[1] ACI Committee 440.1R-15, “Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer Bars”; American Concrete Institute: Detroit, MI, USA, 2015.
[2] Oehlers, D.J. and Seracino R., “Design of FRP and Steel Plated RC Structures: Retrofitting Beams and Slabs for Strength, Stiffness and Ductility”, Elsevier Ltd., 228pp, 2004.
[3] Alexander, S. and Simmonds S., “Shear-moment transfer in slab–column connections”. In Structural Engineering Report; University of Alberta: Edmonton, AB, Canada, pp. 95, 1989.
[4] Guandalini, S., Burdet, O.L., Muttoni A., “Punching tests of slabs with low reinforcement ratios”. ACI Struct. J., v. 106, 87–95, 2009.
[5] Silva, M.A.L., Madushanka, W.I., Ariyasena, P.S.I, Gamage, J.C.P.H, “Punching Shear Capacity Enhancement of Flat Slabs Using End Anchored Externally Bonded CFRP Strips”; Society of Structural Engineers: Colombo, Sri Lanka, 28, 2018.
[6] Rasha, T.S.M, Amr, B., Hany, A., “Effect of flexural and shear reinforcement on the punching behavior of reinforced concrete flat slabs”. Alex. Eng. J. vol. 56, 591–599, 2017.
[7] Al-Qraishi, H., “Detection of fibers content in UHPC slabs”. Eng. & Tech. Journal, vol.33, part(A), No.3, 720–728, 2015.
[8] Sayhood, E.K., Hamood, M.J., Abdul Ridha, A.A., “Punching shear resistance of reinforced concrete flat plate slabs strengthened with CFRP”. Eng. & Tech. Journal, vol.32, part(A), No.2, 511–529, 2014.
[9] Medhlom, M.K., “Punching shear behavior of fibrous self –compacting concrete flat slabs”. Eng. & Tech. Journal, vol.32, part(A), No.12, 2874–2890, 2014.
[10] ACI Committee 318M-318RM, “Building Code Requirements for Structural Concrete and Commentary”: American Concrete Institute: Detroit, MI, USA, 2019.
[11] British Standards Institution BS8110, “Structural Use of Concrete—Code of Practice for Design and Construction”, British Standards Institution, London, UK, 1997.
[12] European Committee for Standardization EN 1992-1-1, “ Eurocode 2: Design of Concrete Structures—Part 1-1: General Rules and Rules for Buildings; The European Union per Regulation 305/2011”, European Committee for Standardization, Brussels, Belgium, 2004.
[13] Canadian Standards Association CAN/CSA S806-12, “Design and Construction of Building Structures with Fiber-Reinforced Polymer”, Canadian Standards Association, Toronto, ON, Canada, 2012.
[14] Harajli, M.H. and Soudki, K.A., “Shear strengthening of interior slab–column connections using carbon fiber-reinforced polymer sheets”. J. Compos. Constr., vol. 7, 145–153, 2003.
[15] Sharaf, M.H., Soudki, K.A., Dusen, M.V., “CFRP strengthening for punching shear of interior slab–column connections”. J. Compos. Constr., vol. 10, 410–418, 2006.
[16] Radik, M.J., Erdogmus, E., Schafer, T., “Strengthening two-way reinforced concrete floor slabs using polypropylene fiber reinforcement”. J. Mater. Civ. Eng. ASCE, vol. 23, 562–571, 2011.
[17] Esfahani, M.R., “Effect of cyclic loading on punching shear strength of slabs strengthened with carbon fiber polymer sheets”. Int. J. Civ. Eng., vol. 6, 208–215, 2008.
[18] Abbas, H., Abadel, A.A., Almusallam, T., Al Salloum, Y., “Effect of CFRP and TRM strengthening of RC slabs on punching shear strength”. Lat. Am. J. Solids Struct., vol. 12, 1616–1640, 2015.
[19] El-Salakawy, E., Soudki, K.A., Polak, M.A., “Punching shear behavior of flat slabs strengthened with fiber reinforced polymer laminates”. J. Compos. Constr., vol. 8, 384–392, 2004.