Al-Shihab, E., Al-Khatib, A., Masudi, S. (2024). Effects of Zingiber Offcianille Essential Oil on Compressive Strength of Fluorescent Orthodontic Adhesive. , 24(1), 211-219. doi: 10.33899/rdenj.2023.137790.1185
Eman S. Al-Shihab; Ali R. Al-Khatib; Sam'an Malik. Masudi. "Effects of Zingiber Offcianille Essential Oil on Compressive Strength of Fluorescent Orthodontic Adhesive". , 24, 1, 2024, 211-219. doi: 10.33899/rdenj.2023.137790.1185
Al-Shihab, E., Al-Khatib, A., Masudi, S. (2024). 'Effects of Zingiber Offcianille Essential Oil on Compressive Strength of Fluorescent Orthodontic Adhesive', , 24(1), pp. 211-219. doi: 10.33899/rdenj.2023.137790.1185
Al-Shihab, E., Al-Khatib, A., Masudi, S. Effects of Zingiber Offcianille Essential Oil on Compressive Strength of Fluorescent Orthodontic Adhesive. , 2024; 24(1): 211-219. doi: 10.33899/rdenj.2023.137790.1185
Effects of Zingiber Offcianille Essential Oil on Compressive Strength of Fluorescent Orthodontic Adhesive
1Department of Pedodontics Orthodontics and Preventive Dentistry, College of Dentistry, Mosul University / Iraq.
2Faculty of Dentistry, Lincoln University College, Petaling Jaya, Selangor, Malaysia.
Abstract
Aims: This study aimed to evaluate the compressive strength of a fluorescent orthodontic adhesive modified by the incorporation of different concentrations of Zingiber officinale essential oil. Materials and Methods: Compressive strength test groups consisted of the control group, orthodontic adhesive modified with 1% Zingiber Officinale essential oil, and 2% groups, (5 specimens for each group). Cylindrical rubbery molds were utilized to fabricate the study specimens; their diameter was three millimetres while their height was six millimetres, each specimen was constructed by utilizing an incremental approach. Each layer of Fix fluorescent orthodontic adhesive was about 2 mm level, the curing light was applied for 20 seconds. A universal testing apparatus with a cross-head velocity of 1 millimetre/ minute was used to assess the compressive strength. Statistical comparisons were conducted at p> 0.05. Results: The compressive strength of the control group was higher thanorthodontic adhesive modified with 1%, and 2% Zingiber Officinale essential oil, but no statistically significant differences were shown among them. Conclusion: The current study concluded that compressive strength reduced after incorporation of Zingiber Officinale essential oil with orthodontic adhesive, however, no evident differences were noticed.